Heat Pump Water Heater

  • Home /
  • Heat Pump Water Heater

Heat Pump Water Heaters for Hotels, Apartments & Residential Projects

Airproz manufactures heat pump water heaters for distributors, HVAC contractors, OEM brand owners and project developers worldwide. Our integrated and split-type models deliver energy-efficient domestic hot water for hotels, serviced apartments, residential homes and commercial facilities — using up to 75% less energy than conventional electric water heaters.

Available in R410A, R32 and R290 refrigerant options, Airproz heat pump water heaters are designed to meet current and upcoming EU F-Gas regulations, SAA requirements for the Australian market, and the growing global demand for high-efficiency, low-carbon hot water systems. Backed by 20+ years of HVAC manufacturing experience, CE and SAA certification, and full OEM support, Airproz is the manufacturing partner behind hot water brands across 100+ countries.


Why Distributors & Installers Choose Airproz Heat Pump Water Heaters

  • Up to 75% Energy Savings — Heat pump technology delivers significantly lower running costs compared to electric and gas water heaters — a key selling point for hotel operators, property developers and residential buyers
  • High Water Temperature Up to 75°C — Suitable for hotels, hospitals and commercial facilities requiring high-temperature hot water for hygiene and legionella compliance
  • R32 & R290 Available — Low-GWP refrigerant options fully compliant with EU F-Gas phase-down regulations and global green energy programmes
  • Integrated & Split-Type Models — All-in-one units for compact installations, and split-type systems for larger capacities or remote installation requirements
  • CE & SAA Certified — Fully compliant for European markets and the Australian market, where SAA certification is required to access state rebate schemes
  • OEM & Private Label Ready — Your brand, your packaging, your documentation — manufactured by Airproz
  • Global Supply — Consistent lead times and full export documentation for distributors across Asia, the Middle East, Australia, Africa and Europe

Key Specifications

Specification Integrated Model Split Model
Type All-in-one (heat pump + tank) Separate heat pump + cylinder
Refrigerant R410A / R32 / R290 R410A / R32 / R290
Max Water Temperature Up to 75°C Up to 75°C
Ambient Operating Range -7°C to 43°C -7°C to 43°C
Certifications CE, SAA, RoHS CE, RoHS
OEM / Private Label Available Available
Lead Time 15–45 days from confirmed order 15–45 days from confirmed order

Application Scenarios

Airproz heat pump water heaters are trusted by project buyers and distributors across three core application areas:

Hotels & Serviced Apartments

High water temperature output up to 75°C makes Airproz heat pump water heaters suitable for hotels, resorts and serviced apartments requiring consistent, high-temperature hot water supply for guest rooms, kitchens and laundry facilities. Our higher-capacity models and cascade system configurations support large hotel installations with demanding hot water requirements.

Residential Homes & Apartments

Our integrated heat pump water heaters are a direct replacement for electric and gas hot water systems in residential homes and apartments. Compact all-in-one design, easy installation and up to 75% energy savings make them an easy sell for distributors — particularly in Australia, where SAA certification opens access to state government rebate schemes, and in Europe, where R290 models align with green energy incentive programmes.

Commercial & Institutional Facilities

Student dormitories, healthcare facilities, sports centres and commercial laundries benefit from the lower operating costs and reliable high-temperature output of Airproz heat pump water heater systems. Split-type configurations and multi-unit installations can be designed for high-demand applications requiring large volumes of hot water.


Integrated vs Split — Which Model Is Right?

Integrated (All-in-One): The heat pump and hot water tank are combined in a single compact unit. Ideal for residential homes and apartments where space is limited. Simpler installation with lower labour cost and no refrigerant pipe runs required.

Split-Type: The heat pump unit and hot water cylinder are installed separately. Preferred for larger tank capacities, installations where the heat pump needs to be located outside or away from living areas, or commercial applications requiring custom tank sizing.


Who We Supply

  • Regional Distributors — Wholesale supply with competitive factory pricing, CE and SAA documentation, and consistent lead times for global markets
  • HVAC Installers & Plumbing Contractors — Project-based supply for residential, hotel and commercial hot water installations
  • OEM Brand Owners — Private label heat pump water heaters with your branding, packaging and multilingual documentation
  • Property Developers — Specification-ready supply for new residential and commercial developments requiring energy-efficient hot water systems

OEM & Private Label

Airproz supports full OEM and private label programmes for hot water brands and distributors worldwide. Whether you are launching a new brand in Australia, Europe or Southeast Asia, we manufacture, certify and document to your market requirements.

  • Your logo on the unit and packaging
  • CE and SAA declarations under your brand name
  • Multilingual user manuals and installation guides
  • R410A, R32 and R290 options to suit your target market requirements

Learn more: Airproz OEM & ODM Manufacturing →


Frequently Asked Questions

How much energy does a heat pump water heater save?

A heat pump water heater typically uses 60–75% less electricity than a conventional electric resistance water heater. Instead of generating heat directly from electricity, it extracts heat energy from the ambient air — delivering 3–4 units of heat for every 1 unit of electricity consumed. For hotels and residential buyers, this translates to significant reductions in utility bills. Read more: Heat Pump Water Heater vs Gas vs Electric

Why does water temperature matter — and can your units reach 75°C?

Higher water outlet temperature is critical for hotels, hospitals and commercial kitchens where hygiene standards and legionella prevention require hot water to be stored and delivered above 60°C. Airproz heat pump water heaters can reach up to 75°C, making them suitable for demanding commercial applications — not just residential use.

What is the difference between R32 and R290 refrigerant?

Both R32 and R290 are low-GWP refrigerants compliant with EU F-Gas regulations. R32 has a GWP of 675 and is the current mainstream choice for most markets. R290 (propane) has a GWP of just 3 — the lowest available — and is increasingly required for products targeting EU green energy subsidies and premium eco-certification programmes. Read more: R32 vs R290 Heat Pump Water Heater Guide

Are your heat pump water heaters SAA certified for Australia?

Yes. Our integrated heat pump water heater models carry SAA certification, making them eligible for state government rebate programmes across Australia. This is a key commercial advantage for Australian distributors, as customers can access significant rebates when replacing electric or gas water heaters with a certified heat pump model.

Do you offer OEM and private label heat pump water heaters?

Yes. We support full OEM and private label programmes for distributors and brands in Australia, Europe, Southeast Asia and beyond. CE and SAA declarations can be issued under your brand name. Contact our OEM team to discuss your market, volume and documentation requirements.


Related Reading


Looking for a reliable heat pump water heater supplier for your distribution network or project?
Contact Airproz Sales Team →