An air-to-air split-system heat pump connects an outdoor compressor and coil to an indoor coil and fan to heat or cool a building. Its benefits include year-round comfort and ducted or ductless layouts; installation requires an approved equipment match, enough capacity at the design temperatures, and suitable airflow, power, refrigerant piping, and drainage. Choose ducted equipment when suitable air ducts exist, or ductless room units when separate room control is needed. For a water-based heating system, evaluate a purpose-built split air-to-water heat pump.
The word split describes where the equipment sits. It does not, by itself, prove that an air conditioner can provide heating. To confirm that a split unit can heat, check its reversible heat-pump operation and heating-capacity data for the exact indoor/outdoor combination.
What Is a Split System Heat Pump?

A split-system heat pump separates an outdoor compressor and heat exchanger from the indoor heat exchanger, then links them with refrigerant piping to heat or cool a building. In an air-to-air system, an indoor fan or air handler distributes the heated or cooled air. The arrangement can use central ducts or individual room units.
In a common air-to-air design, the outdoor unit contains the compressor and a heat-exchanger coil. The indoor side has a coil and fan, either inside a central air handler connected to ducts or inside a wall-mounted, ceiling-mounted, or concealed room unit. The same system can cool in summer and heat in winter because its refrigerant circuit can reverse the direction of heat transfer.
A standard split air conditioner can also have an outdoor unit and indoor coil but be cooling-only. Look for a heating mode, reversible operation, and rated heating-capacity data for the exact outdoor and indoor model combination before calling it a heat pump.
For a product-level example, the Airproz PAT Series heating-and-cooling specifications list both cooling and heating ratings. Compare the exact model, test conditions, refrigerant requirements, and destination-market approvals before selecting it for a project; its rated heating figures are not a cold-weather capacity curve.
A ductless mini-split heat pump is one type of split system heat pump. A central, ducted split heat pump is another. A split air-to-water heat pump uses an indoor hydraulic unit to send heat into water for radiators, underfloor heating, or a tank. This article focuses mainly on air-to-air systems; water-side requirements are different.
How Does a Split System Heat Pump Work?
A split-system heat pump uses a compressor and refrigerant circuit to absorb heat at one coil and release it at the other. A reversing valve lets a reversible system heat indoor air in winter and remove indoor heat in summer. An expansion device lowers refrigerant pressure before heat absorption; sensors and controls coordinate the compressor, fans and operating modes.
What happens in heating mode?
The outdoor coil absorbs heat from outdoor air, and the indoor coil releases that heat into the building. The compressor raises refrigerant pressure and temperature before heat is given to indoor air. The refrigerant then passes through a pressure-reducing device so it can absorb more outdoor heat.
Outdoor air still contains usable thermal energy when it feels cold. But available heating capacity and electrical efficiency change with temperature. For a cold-climate project, compare the model’s published heating output at your winter design temperature with the building’s heating load. Its nameplate capacity at a mild rating condition cannot answer that question.
What happens in cooling and defrost modes?

In cooling mode, the indoor coil absorbs room heat and the outdoor coil releases it outside. During defrost, the system briefly changes operation to remove frost from the outdoor coil. Cooling moisture drains from the indoor coil through a correctly sloped or pumped condensate line.
During cold, damp weather, frost can build up on the outdoor coil. The system may briefly enter defrost to remove it, sometimes reducing indoor heat delivery during that period. This is a normal operating mode, but repeated long defrost cycles, blocked airflow, or weak heat output call for inspection. For the selected model, check the control guide for defrost behavior and whether backup heat is built in or separately controlled.
What Parts Make Up a Split System Heat Pump?

The main parts of an air-to-air split heat pump are an outdoor compressor and coil, an indoor coil and fan or air handler, a reversing valve, an expansion device, refrigerant lines, sensors, and controls. The installed system also needs appropriate electrical connections, airflow, and an indoor condensate drain for cooling operation. The table below connects each part to its job and the model or installation detail to verify.
| Part | What it does | What to verify |
|---|---|---|
| Compressor | Raises refrigerant pressure so heat can be moved between coils | Outdoor model performance tables: capacity and electrical input at the selected conditions |
| Outdoor heat-exchanger coil and fan | Absorbs heat in heating mode; releases heat in cooling mode | Required outdoor clearances, exposure, and heating/defrost operating conditions |
| Indoor coil and air handler or fan unit | Transfers heat to or from indoor air and moves that air into the space | Indoor fan airflow and resistance from ducts and filters (external static pressure), where applicable |
| Reversing valve | Changes the circuit between heating and cooling | Heating and cooling modes shown for the exact reversible model |
| Expansion device | Reduces refrigerant pressure before the absorbing coil | Approved system components and operating mode; location differs by design |
| Refrigerant lines and connections | Carry refrigerant between indoor and outdoor sections | Approved pipe sizes, length, height difference, insulation, and routing |
| Controller, sensors, and electrical circuits | Manage temperature, compressor speed, fan operation, defrost, and protection | Approved indoor/outdoor/controller combination, power supply, and protection requirements |
| Condensate drain | Removes water formed at the indoor cooling coil | Drain route, gravity fall or pump, overflow protection, and cleaning access |
The main heat pump components work as a connected circuit. For example, a correctly sized compressor cannot make up for a blocked air filter or an indoor coil with the wrong airflow. A compatible indoor/outdoor pairing matters as much as each individual part. For a closer look at rotary and scroll mechanisms, our HVAC compressor types guide also explains why inverter speed control is a separate design choice.
Our heat pump schematic diagram guide explains the difference between refrigerant-cycle, electrical, water-piping, and project installation drawings. Use the air-to-air or air-to-water drawing type that matches your system.
Which Split Heat Pump Type Fits Your Building?

Choose a ducted split heat pump when suitable existing ducts serve the rooms; choose a single-zone or multi-zone ductless heat pump when ducts are absent or rooms need separate control. For radiators or underfloor water heating, evaluate a purpose-built split air-to-water system. These arrangements use different indoor equipment and installation methods.
| System type | Best fit | Main installation task | What to watch |
|---|---|---|---|
| Ducted split air-to-air heat pump | Whole-home or building air distribution using ducts | Match outdoor unit, indoor air handler, duct capacity, returns, and controls | Leaky or undersized ducts, airflow, backup heat integration |
| Ductless single-zone mini-split | One room, addition, office, or a separate living area | Mount a room unit and route the lines, drain, and cable to outdoors | Indoor-unit placement, access, condensate route, room coverage |
| Ductless multi-zone mini-split | Several rooms with separate temperature settings | Match several indoor heads to one approved outdoor combination | Shared outdoor capacity, piping limits, room-by-room load balance |
| Split air-to-water heat pump | Hydronic radiators, underfloor heating, or suitable hot-water applications | Connect a compatible indoor hydraulic module and water system | Required water temperature, flow, buffer/controls, freeze protection |
For radiator or underfloor-water projects, a split air-to-water heat pump and a monobloc have different connection layouts. Our R32 monobloc space-heating heat pump is an example of the alternative: its refrigerant circuit stays in the outdoor unit, with water-side design needed for the building. It is not a refrigerant-split air-to-air system.
Reuse existing ducts only when they can carry the airflow the proposed air handler needs and supply the required rooms. Use actual duct measurements and the selected fan performance data, not the fact that the old system once cooled the building.
- Room loads: Confirm which rooms need heating and cooling, including closed-door operation.
- Supply airflow: Compare required air volume (often stated in cubic feet per minute, or CFM) with measured airflow at the registers.
- Fan resistance: Check measured external static pressure—resistance from ducts and filters—against the selected air handler’s fan data.
- Return air: Check that each room has a usable return path when doors are closed.
- Leakage and insulation: Repair leaky or poorly insulated sections, especially outside conditioned space.
If these checks fail, repair or resize the ducts before assuming they save installation cost. If that work is impractical, compare ductless room units instead.
Is a mini-split the same as a split system heat pump?
A heat-pump mini-split is a subset of split-system heat pumps, not a competing technology. “Mini-split” generally refers to compact indoor and outdoor air-conditioning equipment, often ductless. “Heat pump” describes the ability to transfer heat for heating; “split” describes the equipment arrangement.
For more on indoor-head types and zone layouts, see our mini-split air conditioner guide. Also distinguish a multi-split from a conventional single-zone model: the number of connected heads, simultaneous load, and operating modes must agree with the exact manufacturer combination data.
What Are the Pros and Cons of a Split System Heat Pump?
The main benefits are one system for heating and cooling, efficient heat transfer, and flexible indoor layouts. The main trade-offs are installation complexity, outdoor-temperature performance, refrigerant-line limits, and the cost of matching the system to the building.
| Benefit or limitation | What it means in practice | How to respond |
|---|---|---|
| Heating and cooling from one system | One control strategy can serve both seasons | Verify both rated modes on the exact model |
| Lower electricity use than electric resistance heat when COP is above 1 | At the same delivered heat, a heat pump operating above COP 1 uses less electricity than resistance heat | Compare seasonal efficiency and local power price |
| Ductless zoning | Different occupied rooms can have separate setpoints | Match head size and placement to individual room loads |
| Indoor and outdoor placement flexibility | The compressor stays outside while indoor equipment sits near the served space | Check allowable line length, rise, noise, and access |
| Installation can be more involved | Refrigerant, electrical, drainage, wall penetrations, and controls all need correct work | Plan routes and qualified trades before choosing equipment |
| Heat output varies in cold weather | Some units deliver less heat as outdoor temperature falls | Use cold-design capacity, defrost information, and backup strategy |
| Not all indoor combinations are approved | A matching brand name or nominal tonnage does not establish compatibility | Check approved indoor/outdoor combinations and performance data |
If your existing ducts are tight and deliver the right airflow, a ducted split unit can use them efficiently. If the ducts are old, inaccessible, or poorly balanced, fixing them could change the best choice. For a single room, a ductless heat pump avoids new large ducts but leaves a visible indoor head and still needs a proper line and drain route. If you are deciding whether to replace both heating and cooling or retain an existing heater, our heat pump air conditioner pros and cons guide compares those wider choices against the building’s heating demand and local energy prices.
How Do You Size and Select a Split System Heat Pump?
Calculate the building’s heating and cooling loads, then choose an approved indoor/outdoor combination whose output meets those loads at the design conditions. Check low-temperature heating output, cooling capacity, airflow, electrical supply, and permitted piping before confirming the size. Floor area alone misses insulation, windows, climate, air leakage, occupancy, and distribution losses.
Start with heating and cooling loads, not advertised tonnage
Use a room-by-room load calculation to find the actual heating and cooling duty. For U.S. residential work, the DOE Building America guidance calls for ACCA Manual J load calculations and appropriate equipment selection methods, including Manual S. For other buildings and countries, use the locally applicable design method.
As a unit conversion, one refrigeration ton equals 12,000 BTU/h, and 3 tons equals 36,000 BTU/h of nominal cooling capacity. These describe nominal cooling capacity, not guaranteed heating output on the coldest day. Compare the model’s available heating output at the local winter design temperature with the building’s calculated heating load.
Match the exact indoor and outdoor equipment
Use an indoor and outdoor unit combination approved for the selected system, with compatible refrigerant, controls, and documented heating and cooling performance. A central air handler, ductless indoor head, and outdoor condenser cannot be mixed just because their nominal ratings look similar. Where AHRI certification applies, use AHRI certification information to find the official directory and check the exact combination.
Request the model-specific documents that prove the proposed equipment combination and its output.
- Matched models: Exact indoor and outdoor model numbers, the approved combination list, and a certification listing where available and applicable.
- Heating performance: Expanded capacity and electrical-input tables at the local winter design temperature and relevant indoor conditions, not just one mild-weather test point.
- Cooling and airflow: Total and sensible cooling data, minimum/maximum output where published, the required indoor airflow, and electrical characteristics.
- Installation limits: Model-specific manual stating allowed refrigerant line sizes, total line lengths, elevation difference, outdoor clearance, supply voltage, and control requirements.
Read heating capacity at the outdoor design temperature, not only at a mild rating point. Compare cooling sensible and total capacity at the design condition as well. Sensible cooling lowers air temperature; latent cooling removes moisture. The correct balance matters in humid climates and for rooms with large window or equipment loads.
Check efficiency, airflow, electrical supply, and noise
Choose a matched system whose design-condition heating output, indoor airflow, electrical supply and sound rating fit the project. Use SEER2 and HSPF2 to compare rated seasonal efficiency where those metrics apply. SEER2 is a seasonal cooling-efficiency rating; HSPF2 is a seasonal heating-performance rating. Neither replaces the model’s heating output and power input at your winter design temperature.
- Cold weather: Check output and electrical input at the winter design point, defrost behavior, and whether auxiliary heat is needed.
- Air distribution: Check indoor fan capacity, external static pressure (the resistance the fan must overcome in ducts and filters), filter pressure drop, and return-air paths.
- Electrical: Confirm supply voltage, breaker and disconnect requirements, start/run characteristics, and any heater circuit.
- Installation: Check pipe sizes, factory-charge allowance, maximum line length and elevation, mounting clearances, and local refrigerant rules.
- Comfort: Compare indoor and outdoor noise data at relevant operating speeds, not only the quietest advertised setting.
- Winter heat is short: If available output at the design temperature is below the building load, compare a stronger cold-weather model or a documented backup-heat design for the shortfall.
- Cooling or part-load fit is poor: Recheck cooling load and the unit’s minimum output before increasing size; an oversized system can cycle too often in mild weather.
- Air delivery does not work: If measured duct airflow or return paths fail the air handler’s requirements, fix the distribution system or compare separately served ductless zones.
What Does Split System Heat Pump Installation Require?

Installation requires a matched equipment design, suitable positions for both units, approved refrigerant piping, safe power and controls, a working condensate drain, and final commissioning. Commissioning means testing the installed system and recording that it operates as designed. The exact procedure comes from the selected model’s installation manual and the rules at your site. Qualified technicians handle refrigerant piping and electrical connections under the selected model’s instructions and site rules.
1. Confirm the load, equipment combination, and site
Lock down the required output and approved indoor/outdoor pairing before ordering. Record the address or climate design conditions, selected indoor locations, outdoor noise and setback limits, access for maintenance, and supply voltage. A ducted system also needs tested or calculated duct airflow and a return-air path; a ductless system needs the right head position for air throw and room coverage.
For the wider checks across ducted, ductless, and air-to-water projects, use our air source heat pump installation guide. The selected split-system manual still determines its refrigerant connections and commissioning limits.
2. Plan the outdoor unit, line route, and drainage
Choose an outdoor location with the manufacturer’s airflow and service clearances, then trace the pipe and drain paths. Keep the unit above snow or flood exposure where relevant, support it against vibration, and protect it from blocked discharge air. Respect the specified maximum line length, elevation difference, bends, and insulation requirements. Never guess a pipe size from another model.
3. Install and connect the equipment safely
The installer mounts the units, connects approved refrigerant lines, provides drain piping, and completes electrical and control connections. Refrigerant-circuit work includes the model-specific procedures for leak testing, evacuation, and charge verification. In the United States, applicable refrigerant handling is subject to EPA Section 608 requirements; local licensing and codes also apply. Do not energize or charge a new installation until the manufacturer’s prescribed checks have been completed.
For conventional 24V controls, our heat pump thermostat wiring guide explains common thermostat terminal functions. Communicating controllers and ductless mini-splits require their own manufacturer-approved control diagrams.
4. Commission heating, cooling, and condensate operation
Test the installed system in its intended modes and record the results. The installer should confirm air delivery, thermostat or head controls, pipe and electrical connections, condensate flow, and the manufacturer’s relevant operating readings. Where conditions allow, check both heating and cooling; record any mode that could not be tested on that day and arrange its first-season check.
| Handover item | What you should receive | What you can confirm |
|---|---|---|
| Model and pairing | Outdoor and indoor model numbers, approved combination or technical data | Model labels match the provided documents |
| Installed route | Line sizes and route, drain position, indoor/outdoor positions, power and controls | Air inlets and outlets remain clear and service points are accessible |
| Commissioning | Tested modes, operating readings, drain test, leak-test and charge records where applicable | Controls respond, air reaches intended rooms, and condensate drains in cooling mode |
| Operation | Controller instructions, filter access, service schedule and fault contacts | You know how to use the controls, reach the filter, and request service |
If outdoor conditions prevent a heating or cooling mode test, ask the installer to record which test remains open and when it will be completed.
For the extra details of indoor-unit mounting and line routing, see our ductless heat pump installation guide.
How Much Does a Split System Heat Pump Cost to Install and Run?
Installed cost is the price of a matched indoor and outdoor system plus the work for mounting, refrigerant lines, drainage, electrical supply, ducts or room heads, and commissioning. Running electricity cost equals the electricity used under the actual operating conditions multiplied by your electricity rate. A single-zone wall unit, a multi-zone system and a ducted replacement have different installation scopes, so a single price per ton cannot describe all three.
What changes the installation price?
Installation cost increases with additional indoor units, longer refrigerant lines, new electrical circuits, duct repairs, drain pumps, difficult access and extra commissioning work. A short, accessible route with suitable existing wiring needs less site work than a long multi-room installation requiring wall repairs and new ducts.
- Number and type of indoor units and whether ductwork can be reused
- Low-temperature model requirements, controls, and optional backup heat
- Refrigerant piping distance, access, labor, and commissioning effort
- Electrical panel capacity, dedicated circuits, disconnects, and permits
- Local installer rates, taxes, service coverage, and available incentives
Compare written quotes at the same heating load, winter design temperature, and approved indoor/outdoor pairing. Mark each included job and each exclusion; a lower equipment price does not guarantee a lower installed price.
| Quote item | Proposal A | Proposal B | Why it changes cost |
|---|---|---|---|
| Outdoor and approved indoor models | Fill from quote | Fill from quote | Matched equipment, output and number of indoor units |
| Ductwork or room-head installation | Fill from quote | Fill from quote | Reuse, repair, new ductwork or extra heads |
| Refrigerant lines and condensate drains | Fill from quote | Fill from quote | Pipe length, access, pumps and wall repairs |
| Electrical work and permits | Fill from quote | Fill from quote | Circuits, panels, disconnects and local approvals |
| Backup heat and controls | Fill from quote | Fill from quote | Supplemental equipment and integration |
| Startup testing and handover | Fill from quote | Fill from quote | Commissioning, records and follow-up tests |
| Warranty, service and exclusions | Fill from quote | Fill from quote | What the written proposal covers after installation |
How can you estimate electricity cost?
Estimate electricity cost by dividing the delivered heat (kWh) by the system COP at that condition, then multiplying the electricity used (kWh) by the local price per kWh. The simplified relationships are electricity used (kWh) = delivered heat (kWh) ÷ COP and cost = electricity used × electricity rate.
Delivering 10 kWh of heat at COP 3 requires about 3.33 kWh of electricity. At an assumed $0.20 per kWh, that is about $0.67 for that heating energy. If COP falls to 2 under another condition, the same heat requires 5 kWh, or $1.00 at the same assumed price.
For an annual estimate, use the building’s heating and cooling energy needs, the model’s seasonal performance under relevant conditions, electricity tariffs, defrost and backup heat, and real control schedules. For a broader list of price drivers, see our heat pump air conditioner cost guide.
What Should You Check if the System Performs Poorly?

For weak heating, first check the heating mode, setpoint, indoor filter, and outdoor airflow or frost; for leaks, check the visible condensate drain and stop the system if water reaches electrical parts. For uneven room temperatures or high electricity use, check airflow paths and control settings before comparing the installer’s commissioning readings. These observations help distinguish simple airflow or drainage faults from problems that require trained service personnel.
| Observed problem | First safe checks | What the technician should verify |
|---|---|---|
| Weak heating in cold weather | Selected heating mode, setpoint, filters, outdoor snow/air blockage, whether defrost is active | Design-point capacity, defrost faults, airflow, sensor readings, backup heat setup |
| Uneven room temperatures | Open supply and return paths, head placement, closed doors, room setpoints | Room loads, duct balance or head sizing, indoor airflow |
| Water near an indoor unit | Shut down if water reaches electrical parts; check visible drain blockage or overflow | Drain slope, pump, pan, insulation, and cooling-coil conditions |
| High electricity use | Schedules, setpoints, filters, excessive auxiliary heat, long run times | Operating conditions, capacity match, backup-control logic, measured electrical input |
| Repeated stops or error codes | Document exact code, mode, weather, and time of fault | Manufacturer fault procedure, wiring, sensors, refrigerant circuit and protections |
After a repair, repeat the mode and performance check that failed. For example, after clearing a condensate line, run cooling long enough to verify that water leaves through the drain rather than pooling near the wall. Never open a refrigerant circuit or an electrical cabinet as part of a homeowner check.
Which Split System Should You Choose?
Choose a ducted split heat pump when suitable ducts serve the building, or a single-zone heat-pump mini-split for one room without ducts. For rooms with different schedules, compare approved multi-zone systems; for radiator or underfloor-water heating, evaluate a purpose-built split air-to-water heat pump. Confirm the building loads, winter heating output, approved unit pairing and complete installation scope before choosing a specific model.
| Your situation | Start with | Verify before choosing | Change course if |
|---|---|---|---|
| Existing ducts serve all required rooms | Matched ducted heat pump and air handler | Heating/cooling loads, measured duct airflow, return paths and winter output | Duct repairs are too extensive or the air handler cannot meet airflow needs |
| One independent room without ducts | Single-zone heat-pump mini-split | Room load, indoor-head position, line route and drainage | More separate rooms need independent conditioning |
| Several rooms with different schedules | Approved multi-zone mini-split combination | Loads of all rooms, simultaneous outdoor capacity and minimum output | Connected-head limits or very different room loads favor separate systems |
| Radiators or underfloor water heating | Purpose-built split air-to-water heat pump | Required water temperature, flow, hydraulic components and design-day output | The project needs air distribution instead of a compatible water-based system |
Air-to-water models require water-system design; air-to-air heads do not connect directly to radiators. Before comparing a listed split air conditioner with a heat pump, confirm that the exact model has reversible heating operation and rated heating-capacity data.
At Airproz, our air-conditioning product range and space-heating heat pump range are distinct product families. For a proposed system, compare the exact indoor and outdoor model numbers, the approved combination, and its heating-capacity table at the project’s winter design temperature.
Conclusion
A split system heat pump is a practical way to provide heating and cooling when its indoor and outdoor units, capacity, air distribution, and installation all match the building. Ducted systems work well with sound central ductwork; ductless mini-splits suit rooms and zones without ducts. The decisive checks are rated heating output at your winter design temperature, an approved equipment pairing, a workable line and drain route, and correct commissioning. Use the final model data rather than nominal tonnage or the word “split” alone.
Frequently Asked Questions
Can a split system heat pump both heat and cool?
Yes. A reversible split-system heat pump heats and cools by changing the refrigerant flow, while a cooling-only split air conditioner does not provide heat-pump heating. Check the exact indoor/outdoor model combination for both operating modes and published heating capacity.
Does every split system heat pump need an air handler?
No separate central air handler is needed for a ductless mini-split. Its indoor head already has a coil and fan. A ducted split heat pump uses an indoor air handler to move conditioned air through the building’s ducts.
Can I reuse my existing air ducts with a split heat pump?
Yes, if the ducts are appropriately sized, sealed, insulated where needed, and able to deliver the selected air handler’s required airflow. Check supply and return paths and external static pressure before reusing them. Poor ducts can reduce comfort even when the outdoor heat pump is correctly sized.
Can I reuse my old indoor unit or refrigerant lines with a new heat pump?
Reuse an old indoor coil or refrigerant line set only when the new system’s manufacturer-approved combination and installation instructions permit it. Check refrigerant type, pipe dimensions, route limits, line condition, and compatible controls; matching nominal tonnage alone does not establish compatibility.
Will a split system heat pump work below freezing?
Yes, some split-system heat pumps can provide heating below freezing when their published output at the winter design temperature meets the building’s heating load. Compare that model-specific output, efficiency, defrost behavior and operating limits, then size backup heat if the selected system falls short.
How many indoor units can connect to one outdoor heat pump?
The permitted number of indoor units is set by the exact outdoor model’s approved indoor-unit combination table. The number of ports alone is not enough: check permitted head models, combined connected capacity, simultaneous room loads, maximum pipe length, and controls in the manufacturer’s combination tables.
Can I install a split system heat pump myself?
Plan the room layout and access, but use qualified installers for refrigerant piping, electrical connections, and commissioning. Applicable refrigerant rules and electrical codes vary by location. Ask for a model-specific installation record and heating/cooling test results at handover.
Check the Right System for Your Project
The right split-system heat pump matches the building’s room layout, design heating and cooling loads, electrical supply and approved indoor/outdoor combination. Airproz can help identify relevant product families and the model-level performance and installation documents available for comparison. Send us your room layout or duct plan, design conditions, loads, electrical supply, destination market and whether you need ducts, separate room heads or water-based heating.
We can identify relevant Airproz product families and confirm which matched-system data, low-temperature performance tables, installation limits, and market-specific approval information are available for the models under review. Use those documents to compare the proposed configuration and written scope before ordering.