highlights
Heat It. Cool It. Run It Smarter — The R290 Commercial Heating and Cooling Heat Pump.

High
Capacity

Reliable Operation

Smart
Control

Energy
Efficient
What Is the R290 Commercial Heating and Cooling Heat Pump?
The R290 Commercial Heating and Cooling Heat Pump is a three-phase, air-to-water system built for hotels, factories, hospitals, and shopping malls that need reliable year-round heating and cooling from a single outdoor unit. Available in 50kW, 75kW, and 100kW capacities, it delivers heating output from 17.56 to 116.39kW and cooling from 10 to 105.41kW, using natural R290 refrigerant with a GWP of only 3. As a 100kW commercial heat pump manufacturer, AirProz pairs Hitachi DC inverter compressors with dual DC fans to keep large commercial buildings comfortable while cutting electricity use. Browse the full AirProz commercial heat pump range.
AirProz builds every commercial heat pump for hotel heating and cooling, hospitals, schools, and factories that can’t afford downtime. Each unit ships factory-tested with Hitachi or Highly DC inverter compressors, R290 natural refrigerant, and up to 16 units linkable in parallel for large-scale projects.
Our engineering team supports OEM and private-label orders with CE-compliant documentation and responsive after-sales service. See why R290 is becoming the preferred refrigerant for commercial heat pumps across Europe. From single-property retrofits to multi-building developments, AirProz delivers the capacity, efficiency, and support commercial buyers need.
Benefits

Parallel Operation
Up to 16 units linked for flexible capacity.

Modbus Integration
Enables commercial heat pump BMS Modbus integration via RS485 protocol.

Dual Compressor Options
Hitachi or Highly DC inverter compressors used by model.

WiFi Remote Control
Monitor and adjust operation from any smartphone anywhere.

IoT Connectivity
OTA updates and DTU keep data always current.

Power Monitoring
Track daily and long-term electricity consumption trends.
Heat Any Type of Space:
- Hotels & Resorts
- Hospitals & Clinics
- Office Buildings
- Schools & Universities
- Industrial Facilities
- Shopping Malls
- Apartments
- Sports Centers & Gyms
- Wellness Centers
- Restaurants & Cafeterias
- Laundry Facilities
- Public Bathhouses & Spas
- Government Buildings
- Transportation Hubs
- Green Buildings
- Cold Climate Zones
Great customer reviews
The R290 Commercial Heating and Cooling Heat Pump is designed as an outdoor, floor-mounted unit for rooftop or ground-level installation with adequate airflow clearance around the coil and fans. Water piping connections range from 1.5″ on the 50kW model to 2.5″ on the 75kW and 100kW models, with a working water pressure of 0.1–0.3MPa and rated flow rates of 8.6 to 17.2 m³/h depending on capacity.
Units operate reliably in heating mode from -25°C to 45°C (-25°C to 35°C for the 100kW model) and in cooling mode from 16°C to 45°C ambient. Each unit connects to 380–415V/3/50Hz three-phase power and supports commercial heat pump BMS Modbus integration via RS485, allowing installers to link the system into existing building management platforms during commissioning. For refrigerant safety classification (R290 is A3 flammable), refer to the EU’s official guidance on fluorinated and hydrocarbon refrigerants.
We recommend qualified HVAC technicians handle electrical and refrigerant connections.
Installation
At AirProz, we believe in one mission — Innovating Comfort, Accelerating the Energy Transition. Every system we deliver is built upon this vision: combining advanced technology, reliable performance, and everyday comfort for homes and businesses around the world.
Our products are developed in partnership with some of the most experienced and trusted HVAC manufacturers in the industry.
Through rigorous testing and continuous innovation, we ensure that every AirProz solution meets the highest standards of efficiency, durability, and design.
From cooling to heating, we are redefining how comfort is created and sustained — making clean energy not just a choice, but the new standard.
AirProz Commercial Heat Pump Water Heater

Wide Climate Range-Operates from -25°C to 45°C, suited to varied commercial climates worldwide.

Lower Running Costs-High COP up to 6.73 cuts electricity use versus fossil-fuel boilers.

Easy Maintenance-Modular cabinet design simplifies servicing and reduces long-term downtime.

Versatile Applications-Suited to hotels, hospitals, schools, factories, and shopping malls alike.

Proven Reliability-Hitachi and Highly compressors ensure dependable operation in demanding commercial environments.
specs
System Information
| Model: | TP-050TC3 | TP-075TC3 | TP-100TC3 | ||
| Power Supply | V/Ph/Hz | 380~415/3/50 | 380~415/3/50 | 380~415/3/50 | |
| Heating A7W35 | Capacity | kW | 17.56~50 | 20.24-89.93 | 33.95-116.39 |
| Power Input | kW | 2.61~12.88 | 3.65-21.50 | 6.17-27.90 | |
| COP | w/w | 3.88~6.73 | 4.18~5.55 | 4.17~5.50 | |
| Heating A7W55 | Capacity | kW | 17.95~49 | 19.67-91.59 | 30.61-105.02 |
| Power Input | kW | 3.48~17.2 | 5.65-29.36 | 6.45-29.21 | |
| COP | w/w | 2.85~5.16 | 3.08~3.44 | 3.11~3.48 | |
| Cooling A35W7 | Capacity | kW | 10~35 | 11.14–64.45 | 14.81~85.65 |
| Power Input | kW | 3.84~14.50 | 3.04-21.98 | 4.05~29.30 | |
| EER | w/w | 2.41~2.60 | 2.93~3.66 | 2.92~3.66 | |
| Cooling A35W18 | Capacity | kW | 11~38.5 | 14.73-85.22 | 35.55-105.41 |
| Power Input | kW | 3.12~10.01 | 3.12-22.60 | 8.03-31.09 | |
| EER | w/w | 3.45~3.82 | 3.77~4.72 | 3.39~4.43 | |
| ERP Level(Outlet water temperature at 35℃) | A++ | A+++ | A+++ | ||
| ERP Level(Outlet water temperature at 55℃) | A++ | A+++ | A+++ | ||
| MAX. input power | kW | 19.84 | 46 | 61 | |
| MAX. input current | A | 30.30 | 71 | 95 | |
| Refrigerant (GWP) | R290 (3) | R290 (3) | R290 (3) | ||
| Rated water flow | m³/h | 8.60 | 12.9 | 17.2 | |
| Fan quantity | 1 | 2 | 2 | ||
| Fan motor type | DC inverter | DC inverter | DC inverter | ||
| Compressor | Highly DC inverter | Hitachi DC inverter | Hitachi DC inverter | ||
| IP Class | IPX4 | IPX4 | IPX4 | ||
| Sound pressure at 1m distance | dB(A) | 65 | 65 | 67 | |
| Max outlet water temperature | °C | 75 | 80 | 80 | |
| Water piping connections | inch | 1.5″ | 2.5″ | 2.5″ | |
| Water Pressure drop(max) | kPa | 65 | 23 | 25 | |
| Min/Max Water Pressure | MPa | 0.1/0.3 | 0.1/0.3 | 0.1/0.3 | |
| Operating temperature range (Heating mode) | °C | -25~45 | -25~45 | -25~35 | |
| Operating temperature range (Cooing mode) | °C | 16~45 | 16~45 | 16~45 | |
| Unpacked Dimensions ( L×D×H ) | mm | 1155×990×1880 | 2200×1168×2180 | 2200×1330×2375 | |
| Packed Dimensions ( L×D×H ) | mm | 1238×1058×2033 | 2300×1250×2300 | 2300×1430×2500 | |
| Net Weight | kg | 500 | 770 | 900 | |
| Packed Weight | kg | 540 | 820 | 950 | |
| Note: Parameters are subject to change without prior notice. Please refer to the unit nameplate. | |||||