MetalPro Series

R410A Swimming Pool Heat Pump 30 kw

highlights

Heat and Cool Your Commercial Pool Year-Round

High
Capacity

Reliable Operation

Smart
Control

Energy
Efficient

What Is the MP-030TA1 Commercial Swimming Pool Heat Pump?

The AirProz MP-030TA1 is a professional-grade commercial swimming pool heat pump engineered for hotels, resorts, aquatic centers, and large recreational facilities. Delivering 30.0 kW of heating capacity with a COP of 6.06, this commercial swimming pool heat pump provides both heating and cooling functions to maintain precise pool water temperatures in all seasons. According to the IEA’s analysis on heat pump efficiency, modern heat pumps can deliver 3–6 times more energy than they consume — the MS-030TA1’s COP of 6.06 sits at the top of this range. Built with a titanium heat exchanger and R410A refrigerant, the MS-030TA1 operates reliably across -15°C to 43°C — making it a dependable solution for commercial pool operators worldwide.

Why Choose AirProz for Your Commercial Pool?

R32 vs R290 heat pump water heater comparison

AirProz is a dedicated heat pump manufacturer with deep expertise in commercial swimming pool heat pump applications. Every MP-030TA1 unit is factory-tested for performance consistency and built with industrial-grade components for long service life. We offer flexible OEM and private-label programs, responsive technical support, and full MODBUS integration for BMS-connected facilities.

Benefits

High COP

COP up to 6.06, significantly cuts pool heating energy bills.

Heat & Cool

Heats and cools pool water for year-round temperature control.

Cold Start

Operates reliably from -15°C ambient, ideal for cold-climate pools.

Titanium Core

Titanium heat exchanger resists corrosion in chlorinated pool water

MODBUS Link

Built-in MODBUS protocol integrates with commercial BMS systems.

easy-to-install-wrench-blue

Auto Run

Fully automatic operation with auto-defrost and flow switch protection.

Heat Any Type of Space:

  • Hotels & Resorts
  • Hospitals & Clinics
  • Office Buildings
  • Schools & Universities
  • Industrial Facilities
  • Shopping Malls
  • Apartments
  • Sports Centers & Gyms
  • Wellness Centers
  • Restaurants & Cafeterias
  • Laundry Facilities
  • Public Bathhouses & Spas
  • Government Buildings
  • Transportation Hubs
  • Green Buildings 
  • Cold Climate Zones
ductless-places
ductless-places
ductless-places

Great customer reviews

quotes
Great Product!
Simon
Cleveland, GA
quotes
This is an outstanding product at a reasonable price.
Mike
Birmingham AL
quotes
Great mini-split system!
Marq
New Bern, NC
quotes
Installed easily and works very quietly.
Simon
Cleveland, GA
quotes
Excellent! Works great.
Mike
Birmingham AL
quotes
I would buy it again.
Marq
New Bern, NC
INSTALLATION TYPE:
Easy Installation for Any Pool Setup

The MP-030TA1 is designed for straightforward installation by qualified HVAC technicians. The unit requires a 380–415V / 3-phase / 50Hz power supply with a dedicated circuit rated for a maximum current of 11.4A. Water connections use a standard 50mm pipe fitting; minimum water flow of 12.0 m³/h must be maintained and confirmed via the built-in water flow switch before start-up. The horizontal air-discharge design (1003×374×1318mm footprint) allows flexible placement on rooftops, plantrooms, or ground-level plant pads adjacent to the pool plant room. Ensure a minimum clearance of 500mm on all sides for airflow and service access. MODBUS RS-485 wiring should be completed prior to commissioning if BMS integration is required.

Installation

Step 1
Site Planning
Confirm the installation location, system layout, piping route, and project requirements before installation.
Step 2
System Connection
Connect the heat pump with water tanks, circulation pumps, pipelines, or pool heating systems based on the project design.
Step 3
Electrical & Control Setup
Complete power connection, controller setup, protection checks, and smart control configuration.
Step 4
Commissioning & Operation
Start the system, check water flow, temperature, pressure, and ensure stable long-term operation.
andrew
CEO and Founder
Ethan Cole
AirProz Heating & Cooling Solutions
quotes-white

At AirProz, we believe in one mission — Innovating Comfort, Accelerating the Energy Transition. Every system we deliver is built upon this vision: combining advanced technology, reliable performance, and everyday comfort for homes and businesses around the world.

Our products are developed in partnership with some of the most experienced and trusted HVAC manufacturers in the industry.
Through rigorous testing and continuous innovation, we ensure that every AirProz solution meets the highest standards of efficiency, durability, and design.

From cooling to heating, we are redefining how comfort is created and sustained — making clean energy not just a choice, but the new standard.

quotes-white
Standard Features
Checkmark_Cart

MODBUS Communication-Enables seamless integration with hotel and resort building management systems for centralised control.

Checkmark_Cart

R410A Refrigerant-Environmentally responsible refrigerant with stable performance across the full -15°C to 43°C operating range.

Checkmark_Cart

Titanium Exchanger-Delivers long-term corrosion resistance validated for saltwater and chlorinated pools — see ASHRAE pool heating guidelines for material standards.

Checkmark_Cart

Auto Defrost-Automatic defrost cycle prevents ice build-up and maintains heating output during cold ambient conditions.

Checkmark_Cart

WiFi Ready-Supports wireless remote monitoring and control for streamlined commercial pool facility management.

System Information

Model No. MP-005TA1 MP-006TA1 MP-008TA1 MP-012TA1 MP-016TA1 MP-030TA1
Power Supply 220~240V/1/50Hz 380~415V/3/50Hz
Heating Capacity at Air 27℃/24℃, Water 27℃ in, 29℃out
Heating Capacity(kW) 5.0 7.2 9.5 13.0 16.1 30.0
Power Input(kW) 0.86 1.24 1.62 2.25 2.75 4.95
COP 5.84 5.81 5.88 5.79 5.85 6.06
Heating Capacity at Air 15℃/12℃, Water 26℃ in,28℃out
Heating Capacity(kW) 3.6 5.5 7.0 10.0 12.5 23.5
Power Input(kW) 0.73 1.12 1.41 2.05 2.54 4.69
COP 4.94 4.92 4.95 4.88 4.93 5.01
Cooling Capacity at Air 35℃/24℃, Water 29℃ in,27℃out
Cooling Capacity 3.2 5.1 6.5 9.2 11.3 20.0
Power Input(kW) 0.94 1.51 1.90 2.69 3.36 5.78
EER 3.41 3.38 3.43 3.42 3.36 5.78
Max Power Input(kW) 1.16 1.68 2.24 3.24 3.72 6.35
Max Current(A) 5.8 8.5 11.3 16.4 18.8 11.4
Refrigerant R410a R410a R410a R410a R410a R410a
Heat Exchanger Titanium Titanium Titanium Titanium Titanium Titanium
Air Flow Direction Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
Water Flow Volume(m3/h) 2.0 3.0 3.5 5.5 6.0 12.0
Net Dimensions(L*W*H)(mm) 936*385*550 936*385*550 1011*420*614 986*420*798 986*420*798 1003*374*1318
Package Dimensions(L*W*H)(mm) 1055*460*620 1055*460*620 1110*480*670 1115*490*930 1115*490*930 1090*460*1474
Working temperature range(℃) -15~43 -15~43 -15~43 -15~43 -15~43 -15~43
Noise(dB(A)) 48 48 50 52 52 54
Net Weight(kg) 42 46 58 72 85 135
Gross Weight(kg) 48 52 65 87 100 153
Water connection(mm) 50 50 50 50 50 50

Features

info
Commercial Pool Running Cost
Optimised commercial swimming pool heat pump running cost driven by COP 5.01 even at 15°C ambient, cutting seasonal energy spend.
info
Saltwater Compatible
Titanium heat exchanger withstands aggressive saltwater and heavily chlorinated commercial pool environments.
info
Minimal Maintenance
Fully enclosed cabinet with corrosion-resistant panels reduces scheduled maintenance requirements for busy facilities.
info
High Pressure Protection
Dual high-pressure protection circuit safeguards the compressor and extends overall system service life.

Get expert assistance from our team

avatar
avatar
avatar
avatar
avatar
avatar