AquaTherm Series

R410A Commercial Hot Water Heat Pump 19/22KW

highlights

Industrial-Grade Hot Water, Engineered for Demands That Never Stop.

High
Capacity

Reliable Operation

Smart
Control

Energy
Efficient

What is a Commercial Heat Pump Water Heater

The AirProz AT-019K and AT-022K are high-capacity commercial hot water heat pumps designed for continuous, large-scale hot water supply in demanding environments. Delivering up to 22 kW of heating output at a COP of 4.27, these units run on 380–415V three-phase power and operate reliably across an ambient range of -15°C to 43°C. Built with a smart automatic controller and RS485 Modbus communication, they integrate seamlessly into building management systems — no manual intervention required. Whether for a hotel, hospital, school, or industrial facility, the AT series delivers stable 60°C outlet water with minimal energy cost.
Airproz commercial hot water heat pump installed at hospital — high-capacity hot water supply for healthcare facilities

AirProz is a dedicated commercial heat pump water heater manufacturer focused on performance, reliability, and global compliance. Our AT series is engineered specifically for high-demand commercial applications — not residential units scaled up. With a COP exceeding 4.27, built-in multi-layer protection, and native Modbus support for BMS integration heat pump water heater projects, AirProz delivers technology that reduces operating costs from day one. Backed by factory-direct pricing, responsive technical support, and customization capability for OEM partners, AirProz is the supply chain partner built for projects that cannot afford downtime. Learn more about heat pump efficiency standards at the IEA Heat Pumps programme.

Benefits

Modbus

RS485 onboard; integrates with any BMS via Modbus protocol.

Auto Ctrl

Smart controller runs fully automatic; zero manual operation needed.

High COP

COP up to 4.29 — maximizes output per kW of electricity consumed.

Eco Ref

Uses R410A refrigerant; environmentally compliant and globally available.

60°C Out

Delivers stable hot water up to 60°C for high-demand commercial use.

easy-to-install-wrench-blue

Wide Temp

Operates from -15°C to 43°C ambient — year-round reliable performance.

Heat Any Type of Space:

  • Hotels & Resorts
  • Hospitals & Clinics
  • Office Buildings
  • Schools & Universities
  • Industrial Facilities
  • Shopping Malls
  • Apartments
  • Sports Centers & Gyms
  • Wellness Centers
  • Restaurants & Cafeterias
  • Laundry Facilities
  • Public Bathhouses & Spas
  • Government Buildings
  • Transportation Hubs
  • Green Buildings 
  • Cold Climate Zones
ductless-places
ductless-places
ductless-places

Great customer reviews

quotes
Great Product!
Simon
Cleveland, GA
quotes
This is an outstanding product at a reasonable price.
Mike
Birmingham AL
quotes
Great mini-split system!
Marq
New Bern, NC
quotes
Installed easily and works very quietly.
Simon
Cleveland, GA
quotes
Excellent! Works great.
Mike
Birmingham AL
quotes
I would buy it again.
Marq
New Bern, NC
INSTALLATION TYPE:
Commercial Heat Pump Water Heater

The AT-019K and AT-022K are designed for straightforward commercial installation. Both units use a male 25 mm water connection (inlet/outlet), compatible with standard commercial pipework. 

The 380–415V / 3-phase / 50Hz power supply requires a licensed electrician for connection. Units should be installed outdoors or in a well-ventilated plant room on a level concrete pad capable of supporting 163 kg (gross weight). Maintain a minimum clearance of 500 mm on all sides for airflow and service access. 

The RS485 port on the mainboard connects to your BMS via standard Modbus wiring. For hotel hot water heat pump system design guidance, consult your MEP engineer to size buffer tanks and circulation loops based on peak demand. Commissioning requires setting target water temperature (up to 60°C) via the smart controller panel.

Installation

Step 1
Site Planning
Confirm the installation location, system layout, piping route, and project requirements before installation.
Step 2
System Connection
Connect the heat pump with water tanks, circulation pumps, pipelines, or pool heating systems based on the project design.
Step 3
Electrical & Control Setup
Complete power connection, controller setup, protection checks, and smart control configuration.
Step 4
Commissioning & Operation
Start the system, check water flow, temperature, pressure, and ensure stable long-term operation.
andrew
CEO and Founder
Ethan Cole
AirProz Heating & Cooling Solutions
quotes-white

At AirProz, we believe in one mission — Innovating Comfort, Accelerating the Energy Transition. Every system we deliver is built upon this vision: combining advanced technology, reliable performance, and everyday comfort for homes and businesses around the world.

Our products are developed in partnership with some of the most experienced and trusted HVAC manufacturers in the industry.
Through rigorous testing and continuous innovation, we ensure that every AirProz solution meets the highest standards of efficiency, durability, and design.

From cooling to heating, we are redefining how comfort is created and sustained — making clean energy not just a choice, but the new standard.

quotes-white

AirProz Commercial Heat Pump Water Heater

Standard Features
Checkmark_Cart

Multi-Protect-High/low pressure, voltage, temperature, frost & anti-freeze protection built in.

Checkmark_Cart

Inverter Ready-Variable-speed operation adapts output to real-time demand, cutting waste.

Checkmark_Cart

Low Noise-Noise level ≤57 dB — suitable for noise-sensitive hotel and hospital sites.

Checkmark_Cart

Single Comp-One scroll compressor per unit; fewer moving parts mean longer service life.

Checkmark_Cart

Modular Scale-Multiple AT units can be cascaded to meet larger hotel hot water heat pump system design requirements.

System Information

Model No. AT-019K AT-022K AT-032K AT-038K AT-045K
Power Supply 380~415V/3/50Hz
Heating Capacity  (KW) 18.00 22.00 32.00 38.00 47.00
Rated Input Power (KW) 4.20 5.15 7.40 8.75 10.82
Rated Current (A) 7.51 9.21 13.51 15.64 19.34
COP 4.29 4.27 4.32 4.34 4.34
Max Power Input(kW) 7.20 8.70 12.00 13.90 16.23
Max Current(A) 12.90 15.60 21.60 24.85 29.01
Water flow volume(L/h) 4000 4500 6900 8000 9500
Water Pressure Drop(kPa) 50 50 60 60 65
Compressor qty. 1 1 2 2 1
Fan motor qty. 1 1 2 2 1
Dimensions(L*W*H)(mm) 752*691*1000 752*691*1000 1410*748*1000 1410*748*1000 1250*1076*1870
Noise(dB) ≤57 ≤57 ≤59 ≤59 ≤65
Net Weight(kg) 155 155 259 259 450
Water connection(mm) male 25 male 25 female 32 female 32 male 40
Gross Weight(kg) 163 163 269 269 462
Packing Dimensions(L*W*H)(mm) 792*741*1151 792*741*1151 1460*798*1151 1460*798*1151 1250*1076*1870

 

Features

info
Wide Scene
Certified for hotel, hospital, school, and factory hot water applications.
info
Low OpEx
COP 4.27+ cuts energy bills versus gas or electric resistance heating.
info
Long Life
Multi-protection system ensures stable operation and extended unit lifespan.
info
BMS Ready
Native BMS integration heat pump water heater capability via RS485 Modbus — no gateway needed.

Get expert assistance from our team

avatar
avatar
avatar
avatar
avatar
avatar