PoolNova Series

R290 Swimming Pool Heat Pump 020/025kw TA3

highlights

Reliable R290 Pool Heating for High-Demand Projects

High
Capacity

Reliable Operation

Smart
Control

Energy
Efficient

What Is an R290 Swimming Pool Heat Pump?

AirProz is an R290 commercial pool heat pump manufacturer offering two 380–415 V three-phase models for hotels, resorts, villas, and larger pool projects. Maximum heating capacities reach 19.26 and 23.60 kW, while maximum input currents are limited to 7.1 and 10.1 A. Full inverter operation, WiFi control, and heating/cooling modes support dependable daily operation. Explore our commercial heat pump solutions. See the European Commission’s heat pump refrigerant guidance.

Why Choose AirProz for Your Pool Heating Solution?

R32 vs R290 heat pump water heater comparison

For project buyers evaluating an inverter commercial pool heat pump manufacturer, AirProz provides capacity matching, controller options, customized appearance, and technical coordination. Our engineering team supports OEM pool heating heat pump custom requirements for distributors and private-label brands. Choose AirProz as your R290 commercial pool heat pump manufacturer for coordinated OEM development and production support. Review our OEM/ODM heat pump capabilities.

Benefits

Load Matching

Inverter output adapts continuously to changing commercial pool demand.

Remote Management

WiFi enables off-site temperature and operating-mode adjustments.

Seasonal Control

Heating and cooling modes support seasonal project requirements.

Clear Interface

The front display gives operators quick access to essential settings.

Project Controls

Multiple controller options support varied project control layouts.

easy-to-install-wrench-blue

Custom Branding

Custom colors and appearance support private-label product programs.

Heat Any Type of Space:

  • Hotels & Resorts
  • Hospitals & Clinics
  • Office Buildings
  • Schools & Universities
  • Industrial Facilities
  • Shopping Malls
  • Apartments
  • Sports Centers & Gyms
  • Wellness Centers
  • Restaurants & Cafeterias
  • Laundry Facilities
  • Public Bathhouses & Spas
  • Government Buildings
  • Transportation Hubs
  • Green Buildings 
  • Cold Climate Zones
ductless-places
ductless-places
ductless-places

Great customer reviews

quotes
Great Product!
Simon
Cleveland, GA
quotes
This is an outstanding product at a reasonable price.
Mike
Birmingham AL
quotes
Great mini-split system!
Marq
New Bern, NC
quotes
Installed easily and works very quietly.
Simon
Cleveland, GA
quotes
Excellent! Works great.
Mike
Birmingham AL
quotes
I would buy it again.
Marq
New Bern, NC
INSTALLATION TYPE:
Easy Installation for Any Pool Setup

Install the commercial pool heating heat pump outdoors on a reinforced, level base with adequate airflow and service clearance. A qualified electrician must complete the 380–415 V three-phase supply, earthing, breaker selection, phase sequence checks, and commissioning. Use 50 mm water connections with a bypass after the filter and before any chlorinator. Maintain the selected model’s rated flow of 8.30 or 10.20 m³/h and water pressure below 0.4 MPa. Follow local R290 safety codes and keep the unit away from ignition sources.

Installation

Step 1
Site Planning
Confirm the installation location, system layout, piping route, and project requirements before installation.
Step 2
System Connection
Connect the heat pump with water tanks, circulation pumps, pipelines, or pool heating systems based on the project design.
Step 3
Electrical & Control Setup
Complete power connection, controller setup, protection checks, and smart control configuration.
Step 4
Commissioning & Operation
Start the system, check water flow, temperature, pressure, and ensure stable long-term operation.
andrew
CEO and Founder
Ethan Cole
AirProz Heating & Cooling Solutions
quotes-white

At AirProz, we believe in one mission — Innovating Comfort, Accelerating the Energy Transition. Every system we deliver is built upon this vision: combining advanced technology, reliable performance, and everyday comfort for homes and businesses around the world.

Our products are developed in partnership with some of the most experienced and trusted HVAC manufacturers in the industry.
Through rigorous testing and continuous innovation, we ensure that every AirProz solution meets the highest standards of efficiency, durability, and design.

From cooling to heating, we are redefining how comfort is created and sustained — making clean energy not just a choice, but the new standard.

quotes-white
Standard Features
Checkmark_Cart

Natural Refrigerant - R290 refrigerant provides GWP 3 with 0.56 or 0.62 kg charges.

Checkmark_Cart

High COP - COP reaches 16.29 under the specified part-load test condition.

Checkmark_Cart

Outdoor Protection - IPX4 protection supports installation in suitable outdoor locations.

Checkmark_Cart

Water Control - Water settings support 15–40°C heating and 15–28°C cooling operation.

Checkmark_Cart

Noise Control - Rated noise levels are 56 and 58 dB(A), depending on model.

System Information

Model PN-020TA3 PN-025TA3
Power Supply 380–415 V / 3N~ / 50 Hz (60 Hz) 380–415 V / 3N~ / 50 Hz (60 Hz)
Product Technical Data
Heating Capacity 1 Max./Min Air 26°C, humidity 80%, water inlet 26°C / outlet 28°C kW 19.26–1.84 23.60–2.34
Heating Power Input Max./Min kW 3.60–0.113 5.17–0.173
COP Max./Min W/W 5.35–16.29 4.56–13.51
Heating Capacity 2 Max./Min Air 15°C, humidity 70%, water inlet 26°C kW 14.42–2.78 17.90–3.91
Heating Power Input Max./Min kW 3.29–0.392 4.55–0.58
COP Max./Min W/W 4.38–7.09 3.93–6.72
Cooling Capacity Max./Min Air 35°C, water inlet 27°C kW 7.92 –5.13 9.04
Cooling Power Input Max./Min kW 2.10–0.91 2.88
EER Max./Min W/W 3.77–5.64 3.14
Noise level dB(A) 56 58
Power Input Max. kW 4.32 6.2
Current Input Max. A 7.1 10.1
Heating Ambient Temperature ℃ -15–43 -15–43
Cooling  Ambient Temperature ℃ 15–43 15–43
Heating Water-Side Operating Temperature ℃ 15–40 15–40
Cooling Water-Side Operating Temperature ℃ 15–28 15–28
Refrigerant Type / Charge / GWP kg R290 / 0.56 / 3 R290 / 0.62 / 3
CO₂ Equivalent 0.00168t 0.00186t
Operating Pressure (Low Side) MPa 1.1 1.1
Operating Pressure (High Side) MPa 3 3
Maximum Allowable Pressure MPa 3.2 3.2
Electrical Shockproof I I
IP Class IPX4 IPX4
Water Piping Connections mm 50 50
Water Pressure Drop kPa 25 28
Water Pressure Max MPa 0.4 0.4
Water Flow Rated m³/h 8.30 10.20
Unit Dimensions (W/H/D) mm 1056×401×740 1056×401×740

Features

info
Running Costs
Part-load operation helps reduce commercial pool heat pump running cost over extended schedules.
info
Project Applications
Suitable for hotels, resorts, villas, and larger private pool projects.
info
Compact Cabinet
Both models use a compact 1056 × 401 × 740 mm cabinet.
info
Service Support
AirProz provides technical coordination for distributors, contractors, and private-label brands

Get expert assistance from our team

avatar
avatar
avatar
avatar
avatar
avatar