highlights
Monobloc Heating Heat Pump — A+++, R290
Heat to -25°C.

High
Capacity

Reliable Operation

Smart
Control

Energy
Efficient
What is a Monobloc Heating Heat Pump Water Heater
As a R290 space heating heat pump manufacturer EU, AirProz combines low-GWP refrigerant, A+++ efficiency, and stable -25°C operation to meet strict EU eco-design standards. Every monobloc heating heat pump unit features DC inverter compressor and fan, SG-Ready smart grid compatibility, dual-zone control, and 5G/2.4G WiFi—engineered for reliable, future-proof heating performance backed by responsive OEM/ODM support and global certification readiness.
Benefits

R290
Eco refrigerant, ultra-low GWP of 3

A+++
A+++ rated at 35°C and 55°C

-25°C
Reliable heating even in deep cold

75°C
High outlet water for DHW comfort

Inverter
DC inverter compressor and pump

SG-Ready
Smart grid linkage with PV systems
Heat Any Type of Space:
- Hotels & Resorts
- Hospitals & Clinics
- Office Buildings
- Schools & Universities
- Industrial Facilities
- Shopping Malls
- Apartments
- Sports Centers & Gyms
- Wellness Centers
- Restaurants & Cafeterias
- Laundry Facilities
- Public Bathhouses & Spas
- Government Buildings
- Transportation Hubs
- Green Buildings
- Cold Climate Zones
Great customer reviews
This monobloc heating heat pump is designed for compact outdoor installation: place the unit on a level, well-ventilated base with adequate airflow clearance, connect the G1 water piping to your buffer tank or DHW cylinder, and wire the power supply per the rated voltage (220~240V/1Ph or 380~415V/3Ph). The built-in inverter circulation pump and IPX4-rated enclosure simplify setup, while the reserved RS485 port supports BMS or third-party controller integration for space heating heat pump for underfloor heating and cooling systems. For sizing guidance, refer to resources from the European Heat Pump Association.
Installation
At AirProz, we believe in one mission — Innovating Comfort, Accelerating the Energy Transition. Every system we deliver is built upon this vision: combining advanced technology, reliable performance, and everyday comfort for homes and businesses around the world.
Our products are developed in partnership with some of the most experienced and trusted HVAC manufacturers in the industry.
Through rigorous testing and continuous innovation, we ensure that every AirProz solution meets the highest standards of efficiency, durability, and design.
From cooling to heating, we are redefining how comfort is created and sustained — making clean energy not just a choice, but the new standard.
AirProz Commercial Heat Pump Water Heater

Dual Zone-Independent control for two temperature zones

Power Detection-Monitors and optimizes energy consumption

RS485 Ready-Enables BMS and remote integration

Smart Screen-5-inch TFT true color display

PV Linkage-Syncs with solar PV for cost savings
specs
System Information
| Model: | TC-006A1 | TC-008A1 | TC-008A3 | TC-012A1 | TC-012A3 | ||
| Power Supply | V/Ph/Hz | 220~240/1/50 | 220~240/1/50 | 380~415/3/50 | 220~240/1/50 | 380~415/3/50 | |
| Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 2.92~9.1 | 4.10~12.1 | 4.10~12.1 | 4.30~15.20 | 4.30~15.2 |
| Power Input | kW | 0.61~2.11 | 0.79~2.85 | 0.79~2.85 | 0.87~3.73 | 0.87~3.73 | |
| Current Input | A | 2.8~9.25 | 3.45~13.04 | 1.62~4.57 | 4.02~16.38 | 1.78~6.04 | |
| COP | W/W | 4.31-5.66 | 4.24~5.57 | 4.24~5.57 | 4.07~5.57 | 4.07~5.57 | |
| Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 2.99~8.16 | 4.05~12.15 | 4.05~12.15 | 4.25~14.55 | 4.25~14.55 |
| Power Input | kW | 1.03~2.92 | 1.38~4.06 | 1.38~4.06 | 1.45~4.28 | 1.45~4.28 | |
| Current Input | A | 4.57~12.79 | 5.73~17.7 | 2.70~6.43 | 6.71~18.80 | 2.84~6.78 | |
| COP | W/W | 2.79-3.46 | 2.99~3.45 | 2.99~3.45 | 2.83~3.45 | 2.83~3.45 | |
| Nominal Cooling (Max) (A35/24℃,W12/7℃) | Cooling Capacity | kW | 1.38~5.7 | 3.65 | 3.65~8.59 | 3.65~11.04 | 3.65~11.04 |
| Power Input | kW | 0.67~2.44 | ·8.59 | 1.12~3.31 | 1.12~3.97 | 1.12~3.97 | |
| Current Input | A | 3.06~10.27 | 1.12~3.31 | 1.97~5.25 | 5.18~17.44 | 1.97~6.30 | |
| ERP Level(Outlet water temp. at 35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ | |
| MAX. input power | kW | 3.5 | 5.4 | 5.85 | 5.4 | 5.85 | |
| MAX. input current | A | 15 | 25 | 10 | 25 | 10 | |
| Refrigerant / Weight | / | R290 | R290 | R290 | R290 | R290 | |
| Refrigerant Charge | kg | 0.55 | 1.05 | 1.05 | 1.05 | 1.05 | |
| Fan quantity | / | 1 | 1 | 1 | 1 | ||
| Sound pressure at 1m distance | dB(A) | 42 | 46 | 46 | 50 | 50 | |
| Max outlet water temperature | °C | 75 | 75 | 75 | 75 | 75 | |
| Water piping connections | / | DN 25 (1″) | DN 25 (1″) | DN 25 (1″) | DN 25 (1″) | DN 25 (1″) | |
| Rated water flow | m3/h | 1 | 1.4 | 1.4 | 2.06 | 2.06 | |
| Fan Air flow | m3/h | 2500 | 3250 | 3250 | 4500 | 4500 | |
| Fan out put | W | 110 | 150 | 150 | 180 | 180 | |
| Fan Speed | RPM | 600 | 450 | 450 | 600 | 600 | |
| Noise power level | dB(A) | 60 | 58 | 58 | 68 | 68 | |
| Start up Current | A | 2 | 3.5 | 2 | 3.5 | 2 | |
| Max. Outlet water temperature | °C | 75 | 75 | 75 | 75 | 75 | |
| Opearting Ambient temperature | -25-45 | -25-45 | -25-45 | -25-45 | -25-45 | ||
| Water Pressure drop(max) | kPa | 20 | 20 | 20 | 20 | 20 | |
| Operating temperature range (Heating mode) | °C | -25-45 | -25-45 | -25-45 | -25-45 | -25-45 | |
| Operating temperature range (Cooing mode) | °C | 16~45 | 16~45 | 16~45 | 16~45 | 16~45 | |
Features
let's talk
Get expert assistance from our team
- Call our product specialists at: (888) 754-4037
- Sun 10am-3pm, Mon-Fri 7am-7pm, Sat 10am-4pm CT