highlights
Powerful Monobloc Heat Pump for Heating, Cooling, and Hot Water — Engineered for Maximum Efficiency

High
Capacity

Reliable Operation

Smart
Control

Energy
Efficient
What is a Monobloc Heating Heat Pump Water Heater
Choosing AirProz means investing in a reversible air to water heat pump for heating and cooling built for villas and small hotels, vacation homes, and apartment buildings alike. With R290 heat pump advantages EU 2026-ready compliance, AirProz units combine low-GWP refrigerant with industry-leading COP performance up to 5.59 W/W. Every unit undergoes MCS certification testing, ensuring reliability backed by international standards — for verified performance data, buyers can reference the European Commission’s Ecodesign heat pump resources.
Benefits

COP
5.59 W/W boosts winter heating savings

Heating Function
21.90kW covers large villa heating loads

Cooling Function
17.2kW handles peak summer cooling

Max Temp.
75°C output ready for DHW tanks

Working Temp.
Runs steady at -25°C ambient

Water Flow
3.1m³/h suits dual-zone systems
Heat Any Type of Space:
- Hotels & Resorts
- Hospitals & Clinics
- Office Buildings
- Schools & Universities
- Industrial Facilities
- Shopping Malls
- Apartments
- Sports Centers & Gyms
- Wellness Centers
- Restaurants & Cafeterias
- Laundry Facilities
- Public Bathhouses & Spas
- Government Buildings
- Transportation Hubs
- Green Buildings
- Cold Climate Zones
Great customer reviews
Installation requires a stable outdoor concrete base with adequate clearance for the 6000 m³/h fan airflow and 1m sound pressure of 55 dB(A). Connect via DN32 (1-1/4″) water piping to the indoor buffer tank or DHW cylinder, ensuring rated water flow of 3.1 m³/h is maintained. Power supply varies by model (220-240V/1/50 for TC-018A1, 380-415V/3/50 for TC-018A3) — verify max input current (35A or 17A) matches your electrical circuit before commissioning. The 5-Inch TFT touchscreen controller and WiFi module allow remote monitoring once connected to the home network. Professional installation by a certified technician is strongly recommended to ensure correct refrigerant handling and system commissioning.
Installation
At AirProz, we believe in one mission — Innovating Comfort, Accelerating the Energy Transition. Every system we deliver is built upon this vision: combining advanced technology, reliable performance, and everyday comfort for homes and businesses around the world.
Our products are developed in partnership with some of the most experienced and trusted HVAC manufacturers in the industry.
Through rigorous testing and continuous innovation, we ensure that every AirProz solution meets the highest standards of efficiency, durability, and design.
From cooling to heating, we are redefining how comfort is created and sustained — making clean energy not just a choice, but the new standard.
AirProz Commercial Heat Pump Water Heater

Eco Refrigerant-R290 (GWP=3) meets EU 2026 green targets

Smart Display-5-inch TFT screen for on-site control

Remote Access-5G/2.4G WiFi monitors villa or hotel units

Solar Sync-PV linkage cuts grid costs on sunny days

Dual Zones-Separate heating/cooling for multi-room homes
specs
System Information
| Model: | TC-018A1 | TC-018A3 | ||
| Power Supply | V/Ph/Hz | 220~240/1/50 | 380~415/3/50 | |
| Nominal Heating (Max) (A7/6℃,W30/35℃) | Heating Capacity | kW | 7.24~21.90 | 7.24~21.90 |
| Power Input | kW | 1.50~5.88 | 1.50~5.88 | |
| Current Input | A | 6.86~30.25 | 2.82~9.16 | |
| COP | W/W | 3.82~5.59 | 3.82~5.59 | |
| Nominal Heating (Max) (A7/6℃,W47/55℃) | Heating Capacity | kW | 6.36~19.45 | 6.36~19.45 |
| Power Input | kW | 2.15~6.85 | 2.15~6.85 | |
| Current Input | A | 9.84~30.12 | 3.71~10.6 | |
| COP | W/W | 2.84~3.57 | 2.84~3.57 | |
| Nominal Cooling (Max) (A35/24℃,W12/7℃) | Cooling Capacity | kW | 4.55~17.2 | 4.55~17.20 |
| Power Input | kW | 1.85~7.31 | 1.85~7.31 | |
| Current Input | A | 8.47~32.1 | 2.99~11.26 | |
| ERP Level(Outlet water temp. at 35℃) | / | A+++ | A+++ | |
| MAX. input power | kW | 7.5 | 10.5 | |
| MAX. input current | A | 35 | 17 | |
| Refrigerant / Weight | / | R290 | R290 | |
| Refrigerant Charge | kg | 1.4 | 1.4 | |
| Fan quantity | / | 2 | 2 | |
| Sound pressure at 1m distance | dB(A) | 55 | 55 | |
| Max outlet water temperature | °C | 75 | 75 | |
| Water piping connections | / | DN 32 (1-1/4″) | DN 32 (1-1/4″) | |
| Rated water flow | m3/h | 3.1 | 3.1 | |
| Fan Air flow | m3/h | 6000 | 6000 | |
| Fan out put | W | 220 | 220 | |
| Fan Speed | RPM | 750 | 750 | |
| Noise power level | dB(A) | 72 | 72 | |
| Start up Current | A | 6 | 3.5 | |
| Max. Outlet water temperature | °C | 75 | 75 | |
| Opearting Ambient temperature | -25-45 | -25-45 | ||
| Water Pressure drop(max) | kPa | 55 | 55 | |
| Operating temperature range (Heating mode) | °C | -25-45 | -25-45 | |
| Operating temperature range (Cooing mode) | °C | 16~45 | 16~45 | |
Features
let's talk
Get expert assistance from our team
- Call our product specialists at: (888) 754-4037
- Sun 10am-3pm, Mon-Fri 7am-7pm, Sat 10am-4pm CT