TurboCool PAT Series

R410A T1 Inverter Air Conditioner -PAT Seires

highlights

Compact Power, Year-Round Comfort — The R410A T1 Inverter Air Conditioner Built for Every Home.

affordable

Affordable performance

quiet-speaker

Quiet
comfort

reviews

High preesure protection

easy-to-install-wrench

Easy
installation

What Is the AirProz R410A T1 Inverter Air Conditioner?

The AirProz TCI1-DNPAT Series is a compact residential split-system R410A T1 inverter air conditioner offered in 9K and 12K BTU capacities. Engineered to T1 climate classification, it delivers reliable heating and cooling on a single 220V–240V household circuit. Both models share the same GMCC rotary compressor and identical 3,120 ±5% compressor capacity, ensuring consistent factory output across the range. For buyers evaluating heat pump refrigerant R32 vs R410A, this series uses R410A — a globally proven refrigerant with established service infrastructure, making installation and long-term maintenance straightforward in markets worldwide.

AirProz is a factory-direct air conditioner heat pump manufacturer with full control over component sourcing, assembly, and quality validation. The TCI1-DNPAT Series is engineered for air conditioner heat pump energy efficiency, delivering a COP of up to 3.135 in heating mode and EER of up to 2.144 in cooling — benchmarks aligned with efficiency standards referenced by the International Energy Agency (iea.org). Both models achieve moisture removal of 0.841–0.98 L/h, adding dehumidification value beyond simple temperature control. For distributors and residential contractors, AirProz offers a consistent, well-specified product line with factory-guaranteed performance tolerances.

Benefits

T1 Rated

Certified for T1 climate conditions across global markets.

R410A Gas

Proven refrigerant with worldwide service availability.

Dual Sizes

9K and 12K BTU options for different room size needs.

GMCC Motor

GMCC rotary compressor in both model variants.

Low Draw

Max current as low as 5 A on the 9K DNPAT model.

Dual Mode

Single unit delivers both full heating and cooling output.

Heat or Cool Any Type of Space:

  • Entire homes
  • Small businesses
  • Pool houses
  • Attics
  • Basements
  • Condos
  • Studios
  • Workshops
  • Casitas
  • Garages
  • Bonus rooms
  • Tiny homes
  • Offices
  • Retreat spaces
  • Enclosed porches
  • Hotel rooms
  • Coffee shops
  • Man caves
  • Sun rooms
  • Mother-in-law apartments
ductless-places
ductless-places
ductless-places

Great customer reviews

quotes
Great Product!
Simon
Cleveland, GA
quotes
This is an outstanding product at a reasonable price.
Mike
Birmingham AL
quotes
Great mini-split system!
Marq
New Bern, NC
quotes
Installed easily and works very quietly.
Simon
Cleveland, GA
quotes
Excellent! Works great.
Mike
Birmingham AL
quotes
I would buy it again.
Marq
New Bern, NC
INSTALLATION TYPE:
Split System

The TCI1-DNPAT Series R410A T1 inverter air conditioner is engineered for straightforward split-system installation by a certified HVAC technician. 

Both models operate on a standard single-phase 220V–240V, 50Hz supply, requiring no special electrical upgrades in typical residential settings. 

R410A refrigerant line sets should be connected with approved fittings and pressure-tested for leaks prior to startup. 

Mount the outdoor unit on a firm, level surface with adequate airflow clearance; position the indoor unit to distribute conditioned air evenly across the room. 

The factory-set internal thermal protector requires no field adjustment. Always follow local electrical codes and applicable refrigerant handling regulations throughout installation.

Installation

ductless-install
Step 1
Mount
Once you have received the product, mount the indoor and outdoor units to your desired resting location.
ductless-install
Step 2
Connect
Next, run the line sets, drain line, and electrical wires from the indoor unit(s) to the outdoor unit.
 
ductless-install
Step 3
Electrical
Run a 220 volt power circuit from your main breaker to the outdoor disconnect. Then run the electrical whip from the disconnect to the outdoor unit.
ductless-install
Step 4
Pro Start Up
We’ll help you get an HVAC contractor who will pressure test the line sets, check for leaks, and release refrigerant.
 
andrew
CEO and Founder
Ethan Cole
AirProz Heating & Cooling Solutions
quotes-white

At AirProz, we believe in one mission — Innovating Comfort, Accelerating the Energy Transition. Every system we deliver is built upon this vision: combining advanced technology, reliable performance, and everyday comfort for homes and businesses around the world.

Our products are developed in partnership with some of the most experienced and trusted HVAC manufacturers in the industry.
Through rigorous testing and continuous innovation, we ensure that every AirProz solution meets the highest standards of efficiency, durability, and design.

From cooling to heating, we are redefining how comfort is created and sustained — making clean energy not just a choice, but the new standard.

quotes-white

AirProz R410A T1 Inverter Air Conditioner

Standard Features
Checkmark_Cart

Inverter Technology-Inverter heat pump vs fixed speed: variable output reduces energy waste during operation.

Checkmark_Cart

Twin Model Range-9K and 12K BTU variants allow accurate right-sizing for compact or mid-size rooms.

Checkmark_Cart

Active Dehumidification-Both models remove 0.841–0.98 L/h of moisture for improved indoor comfort daily.

Checkmark_Cart

±5% Compressor Tolerance-Factory-controlled variance on compressor capacity ensures repeatable performance output.

Checkmark_Cart

Matched Compressor- PairIdentical GMCC compressor spec across both models simplifies spares and servicing.

System Information

Specification TCI1-12DNPAT TCI1-09DNPAT
Power Supply 1Ph-220V~240V-50Hz 1Ph-220V~240V-50Hz
Cooling Capacity (Btu/h) 10839 9631
Cooling Capacity (W) 3176.659 2822.696
Cooling Input Power (W) 1683.464 1316.676
Cooling Rated Current (A) 7.664 5.996
EER (W/W) 1.887 2.144
Heating Capacity (Btu/h) 12397 11782
Heating Capacity (W) 3633.236 3452.999
Heating Input Power (W) 1158.855 1139.533
Heating Rated Current (A) 5.28 5.194
COP (W/W) 3.135 3.03
Moisture Removal (L/h) 0.98 0.841
Max. Input Consumption (W) 1286 1058
Max. Current (A) 6 5
Compressor Model KSK103D53UFZ KSK103D53UFZ
Compressor Type Rotary Rotary
Compressor Brand GMCC GMCC
Compressor Capacity 3120 ±5% 3120 ±5%
Compressor Input Power (W) 810 ±5% 810 ±5%
Compressor Rated Current RLA (A) 5.7 ±5% 5.7 ±5%
Thermal Protector Position Internal Internal
Refrigerant Oil Charge (ml) 320 320

Features

info
Global Voltage Ready
220V–240V 50Hz supply suits homes across EU, AU, Middle East, and Asian markets.
info
Low Operating Cost
EER up to 2.144 keeps daily electricity use low during extended summer cooling seasons.
info
Air Conditioner Heat Pump Energy Efficiency
COP of 3.03–3.135 delivers over 3× heat output per watt consumed for lower energy bills.
info
Easy to Service
R410A is globally stocked, keeping routine maintenance accessible and affordable worldwide.

This System Includes*

Desert Climate HVAC

Outdoor Unit x1

T3 Fixed-Speed Outdoor Condenser
High Ambient Temperature

Indoor Unit x1

Wall Mounted Air Conditioner
bmmwmremote

Remote Controller x1

Wireless Remote Control

Get expert assistance from our team

avatar
avatar
avatar
avatar
avatar
avatar